The short answer: the EmberSafe™ FR variant of NIPA synthetic palm thatch is rated Class A to ASTM E108, tested by Intertek, an independent international testing lab for building materials. It means the tested assembly withstood the most severe exposure the standard defines for a fire reaching the roof from outside. It does not mean the roof cannot burn, that a kitchen under the palapa is taken care of, or that the project has its permit. The standard version has no rating. That is why, in a data sheet or a quote, “Class A ASTM E108” must always go together with “FR variant”.
Behind that answer are three distinctions that help when specifying, a note on authorities and insurers, and a short list of what to ask your supplier for.
Fire rated synthetic thatch vs standard: what is the difference?
They are two versions of the same system, with different prices. The FR version includes additives that make ignition harder and slow flame spread, and it is the only one with Class A. The standard version is not rated and is a reasonable choice where there is no fire nearby and no written requirement.
If the decision starts with the roofing material, our synthetic vs natural thatch comparison separates that criterion from the other costs and uses. If you need to compare figures, on our synthetic thatch prices page we explain what the quote for each version depends on.
The two can be combined in the same hotel:
| Situation | Version | Reason |
|---|---|---|
| Grill, open kitchen or fireplace under the roof | FR | There is a permanent heat source close to the roof |
| High-occupancy restaurant, bar or lobby | FR | This is where authorities and insurers tend to pay the most attention |
| Adjacent roofs or roofs close to guest rooms | FR | Behavior against burning brands is part of what the test evaluates |
| Written requirement from the insurer or fire department | FR | The requirement is met with the rated version |
| Isolated kiosk, with no heat sources nearby | Standard or FR | The designer decides |

What does the test assess, and what is ASTM E108 Class A?
ASTM E108 does not test a building. A section of roof covering is built at a defined pitch and subjected to the methods of the ASTM E108 standard: intermittent flame —to see whether fire penetrates the roof covering—, flame spread across the surface and a burning brand placed on it, plus flying brands and, for some treated materials, a rain test. Class A is the most demanding of its three classes: the standard describes it as effective against severe fire exposure; B and C correspond to moderate and light exposures.
The result describes that assembly. In a specification, the precise way to name it is: NIPA synthetic thatch, FR version, Class A rating to ASTM E108. If your project needs to compare the tested configuration with the one to be built, the test report is the document that shows it, and we share it on request.
Nor does the test assess the timber structure, smoke or evacuation. Those remain part of the project.
In specifications and quotes the standard also appears written as “ASTM E-108”: it is the same document. What changes from one product to another is the class obtained and the configuration tested.
| Class under ASTM E108 | Exterior fire exposure it withstands | In NIPA synthetic thatch |
|---|---|---|
| Class A | Severe | FR variant, tested by Intertek |
| Class B | Moderate | — |
| Class C | Light | — |
| Unrated | Not tested | Standard version |
Does Class A fire rated thatch cover a fire that starts under the roof?
ASTM E108 simulates a fire arriving from outside: brands flying from a nearby fire or flame on the roof surface. The standard itself makes it clear: its tests cannot determine performance against a fire that starts inside the building.
A fire that starts under the roof is a different problem. The grill, a kitchen hood, a chimney passing through the roof or the electrical installation are handled through design: distance between the heat source and the thatch, extraction, protection where ducts pass through, and detection.
It also helps to be precise with words. NIPA panels are made of high-density polyethylene (HDPE), a combustible material like other common plastics. The FR version delays ignition and slows the flame, but it does not make the roof non-combustible; that is why we do not call it “fireproof”.

Does ASTM E108 Class A replace a permit?
No. The rating is technical evidence. The permit is granted by each country's authority under its own framework: Protección Civil in Mexico, the fire department or the local authority in other countries. The insurer, for its part, sets its conditions by looking at the whole picture: roofing material, detection, suppression and the hotel's protocols.
Some regulations use other criteria. In Colombia, for example, Title J of NSR-10 (section J.3.11) classifies interior finishes by flame spread and smoke development, which is a different question from the one ASTM E108 answers. How the roof is classified under local regulations is defined by the project's fire protection engineer.
Fire rated synthetic thatch: which certificate should you ask for?
Ask for the ASTM E108 test report for the product and the variant you are being quoted, not a seal or a catalog phrase. Synthetic thatch burns, like any plastic; what changes is how it behaves against exterior fire, and only the report proves that. Check that it states:
- The product name and the exact variant (for NIPA, the FR variant).
- The laboratory that performed the test (for NIPA, Intertek).
- The standard and the class obtained: A, B or C.
- The tested configuration: pitch, deck and fastening of the roof covering.
- The report date and reference number, so your insurer can verify it.
Phrases worth clarifying before you sign
If a quote only says “synthetic palm leaf Class-A certification”, ask which variant it is, which laboratory tested it and under which standard. The class belongs to a tested assembly, not to a brand in general.
The same goes for a “Class A fire retardant” applied to leaf already installed to make fire retardant thatch: ask under which standard and on which material it was tested, and how often it has to be reapplied. NIPA's FR variant has the flame-retardant additives built into the material; it does not depend on a later treatment. If your case is a natural leaf palapa you want to protect, our fire retardant guide for palapas explains the options.
Nor should Class A be confused with LEED certification. LEED rates the sustainability of the whole building (energy, water, materials) and does not classify roof coverings for fire. They are different documents requested for different reasons.

What else backs NIPA's FR variant besides ASTM E108 Class A?
If your resort needs Class A fire rated thatch on restaurants and areas with fire, NIPA's FR variant is the best choice in synthetic thatch for your project: it combines the fire rating with the same warranty, the same wind resistance and the same look as the standard version. NIPA® has been a direct manufacturer since 2010.
These are the figures you can cite in a specification; the full detail is in the NIPA synthetic palm thatch data sheet, and if you are just starting to plan your roof, our palm thatch roof guide brings together the rest of the decisions.
| Specification | NIPA synthetic palm thatch |
|---|---|
| Fire | The FR variant has a Class A rating to ASTM E108 (Intertek); the standard version is not rated |
| Warranty | 20 years against rot, deterioration and sudden color loss |
| Wind | Wind resistance of 260 km/h, installed to NIPA specifications |
| UV | 5,000 hours of testing to ASTM G155 at an independent laboratory |
| Panel | 93 × 70 cm, about 1.0 mm thick; 5.2 pieces per m² |
| Minimum pitch | 18°, over battens (open battening) |
What if there is already a written requirement?
If the insurer or the authority has already asked for something specific, that document is the best starting point. Send it to us with the drawings or a sketch of the areas through the contact form. We will tell you which areas would take the FR version, calculate the panels for each version and share the FR technical documentation with you.

Sources
- ASTM International. ASTM E108: fire test methods for roof coverings (Classes A, B and C). store.astm.org
- Colombian Ministry of Housing, City and Territory. Colombian Earthquake-Resistant Building Code NSR-10, Title J, section J.3.11.
- NIPA Palma. ASTM E108 test report for the FR version, issued by Intertek. Available on request.
Frequently asked questions
Does synthetic thatch burn?
Yes. NIPA panels are made of high-density polyethylene (HDPE), a combustible material like other common plastics. NIPA's FR variant includes additives that make ignition harder and slow flame spread, and it has a Class A rating to ASTM E108. No polyethylene synthetic thatch is non-combustible.
Is all synthetic thatch Class A fire rated?
No. Only thatch with an ASTM E108 test report showing that class. At NIPA, the FR variant has a Class A rating to ASTM E108; the standard version is not rated.
What does Class A fire rated thatch mean on a palapa?
That the tested roof assembly withstood the most severe ASTM E108 exposure to exterior fire: flame, spread and brands. It does not prevent the palapa from burning, nor does it cover a fire that starts under the roof, which is handled with clearances, extraction and detection.
Is a US standard valid in my country?
It serves as technical evidence. The project permit is still granted by the local authority, under its own regulatory framework.
What documentation can I give my insurer?
The technical documentation for the FR version, which we share on request. With it, your insurer or fire protection engineer can see what was tested and with what result.
Let’s talk about your project
NIPA® has manufactured synthetic thatch since 2010, and NIPA Palma, its regional office for Mexico and Latin America, quotes each version factory direct. Send us drawings or photos and we will tell you which areas would take the FR variant, with the test report for the quoted product. WhatsApp +1 (863) 243-0114 or sales@nipapalma.com.